vECTOR 1950MT
The best choice for powerful refrigeration, combining high capacity with a wide range of evaporators.
- Multi zone control
- High performance cooling
- Large choice of evaportors
- City Version
Vector 1950 MT combines high refrigeration capacity with flexible compartment configuration. It is perfect for the transportation of sensitive goods, intensive distribution, multiple door openings and multi-temperatures with a capacity of 18 600 Watts. It is the best choice for powerful refrigeration, combining high capacity with a wide range of evaporators
Refrigeration Capacity
(System net cooling capacity under A.T.P. Conditions at 30° C ambient)
Principal MVS 700 / MVS1100 / MVS2200 / MVD1100 / MVD 2200
Nominal capacity (-20°C/30°C) (W)9800/9800/9800/9800/ 9800/9800
Capacity on engine power 0°C (W)18200/6980/10210/ 13940/10150/15740
Capacity on engine power -20°C (W)9410/4060/5670/7630
5560/8030
Capacity on electrical stand by 0°C (W)15340/5950/9780/
13190/9720/14630
Capacity on electrical stand by -20°C (W)9080/4060/5370/
6970/5420/7840
Heating Capacity
Principal MVS 700 / MVS1100 / MVS2200 / MVD1100 / MVD 2200
Diesel High speed 18°C/-18°C (W)9500/3000/4500/7500/6000/7500
Standby 18°C/-18°C (W)8 840/3 000/4 500/7 500/6000/7 500
Airflow
(High speed engine operation)
Principal MVS 700 / MVS1100 / MVS2200 / MVD1100 / MVD 2200
(AMCA 21 085) m3/hr5 7001 0352 0753 5002 3053 805
Weight
(Including battery)
S version (Standard)945 kg103 dB
T version (Low Noise)951 kg101 dB
Engine
(n° of cylinders - cm3)
ModelCT 4-134DI
Displacement2200 cm3
n° of cylinders4
Maintenance Interval1500 hrs
Compressor
Model06D
Displacement660 cm3
n° of cylinders6
Electrical Stand by Motor
Voltage / Phase / Frequency 400/3/50 Hz
Rating23 kW
Refrigerant Charge
RefrigerantR-404A
ChargeDepending on configuration
Sound pressure
StandardLow Noise
High Speed 75,8 dBA 72,8 dBA
Low Speed71,6 dBA 67,3 dBA
Standby67,8 dBA-
Unit
Dimensions (D x W x H)2050 x 430 x 2227 mm
Body openingL 1700 x H 1170 mm