SUPRA 1150MT
BENEFITS
- Constant evaporator airflow
- Robust design
- High reliability
- Extreme low-noise capabilities
- High cooling performance
Refrigeration Capacity
(System net cooling capacity under A.T.P. Conditions at 30° C ambient)
MTS 700MTS 1100MTS 1450MTS 2200MTD 1450MTD 2200
Nominal capacity (-20°C/30°C) (W)6 4506 4506 4506 4506 4506 450
Capacity on engine power 0°C (W)5 3007 8509 30010 0008 95010 750
Capacity on engine power -20°C (W)3 3004 5505 2005 6005 1005 500
Capacity on electrical stand by 0°C (W)5 3507 2008 3009 0008 0009 450
Capacity on electrical stand by -20°C (W)3 1004 3504 6004 7004 5004 650
Heating Capacity
MTS 700MTS 1100MTS 1450MTS 2200MTD 1450MTD 2200
Diesel High speed 18°C/-18°C (W)4 6804 7104 8905 2004 8905 200
Standby 18°C/-18°C (W)4 2704 3204 5304 7704 5304 770
Airflow
(High speed engine operation)
MTS 700MTS 1100MTS 1450MTS 2200MTD 1450MTD 2200
(AMCA 21085) m3/hr1 1002 1002 4003 5002 3503 600
Weight
(Including battery)
S version (Standard)576 kg
Engine
ModelCT3-69TV
Displacement1123 cm3
n° of cylinders3
Maintenance Interval1000 hrs
Compressor
Model05K4
Displacement400 cm3
n° of cylinders4
Electrical Stand by Motor
Voltage / Phase / Frequency230/400/3/50 Hz
Rating9 kW
Refrigerant Charge
RefrigerantR-404A
ChargeDepending on configuration
Sound Pressure
High speed69,2 dBA
Low speed65,7 dBA
Standby62,2 dBA
Unit
Dimensions971 x 1995 x 684 mm
Body openingL 100 x H 100 mm